AE100 Evaporation Radioactive Isotope Concentration

The World's ONLY

Amerlab specialized the level sensor developed for acid evaporation or isotope concentration experiments after acid digestion. The sensor can maintain its precision even with very low liquid volume such as when the evaporation process nears its end. With this unique level sensor, the AE100's endpoint identification triggers the heater stop and forces air cooling automatically.

Why AE100?

Comprehensive Excellence

Exceptional efficiency

AE100 Evaporation Radioactive Isotope Concentration System evaporates the acid under negative pressure. Within 40 minutes, it can evaporate 10mL nitric acid to 1.5mL. Additionally, warming up and cooling down is rapid. One batch of the samples can be processed in about an hour!

Evaporation Radioactive Isotope Concentration

Incomparable uniformity

The AE100 Evaporation Radioactive Isotope Concentration System is optimized for both heating and gas distribution. Differences between samples are minimized to ensure a consistent rate of evaporating. The following are the testing results. The default endpoint is 1.0mL.

Evaporation Radioactive Isotope Concentration

Confident spiking recovery

Efficiency and uniformity are ensured and the recovery is certain even with volatile elements such as mercury.

Acid Evaporation Radioactive Isotope Concentration Evaporator concentrator

Acid waste recycling

In response to the risk of a room full of toxic fumes, the AE100 Acid Evaporator is equipped with Amerlab's proprietary acid vapor scrubber. The acid vapor is condensed, collected, neutralized, online pH monitored and alkaline sorbent neutralized before being discharged. With this device, the AE100 Acid Evaporator does not need a fume hood.

Furthermore, the collected waste acid can undergo purification using an Acid Purifier for subsequent reuse.

Evaporation Radioactive Isotope Concentration
Evaporation Radioactive Isotope Concentration

Easy to use

Unlike the conventional vacuum acid evaporator, the AE100 uses a unique integrated sealing module. This way, there is no manual screwing of each cap which would be very cumbersome. Instead the complete sealing of the digestion tubes is just one step. In addition, the AE100 software guides you step by step to complete the entire test. Even a layman can easily operate it!

AE100 Evaporation Radioactive Isotope Concentration

Documents Download

Brochure:

Brochure_AE100 Evaporation System, Radioactive Isotope Concentration System